Francais English
22
INT-AI-HE10

8 channels - Analog Input (4-20mA) 2, 4 wires. HE10-16 connector for connection with DCS or PLC.

Browse

CBL-2HE1016/384-2

Browse

VE4003S2B4_SE4003S2B4

Emerson

DeltaV™

Analog Input card, 8 channel, 4-20 mA, HART, 2-wire, 16 pin Mass Termination Block

Max. CBL Length : 5m
25
INT-AI-F-HE10

8 channels - Analog Input (4-20mA) 2, 4 wires with fuse (100mA). HE10-16 connector for connection with DCS or PLC.

Browse

CBL-2HE1016/384-2

Browse

VE4003S2B4_SE4003S2B4

Emerson

DeltaV™

Analog Input card, 8 channel, 4-20 mA, HART, 2-wire, 16 pin Mass Termination Block

Max. CBL Length : 5m
27
INT-AI8-ISO

8 channels - Isolated Analog Input. (4-20mA) 2,4 wires for standard or smart (HART protocol) transmitters. 1-5Vdc. SUBD25 or HE10-16 connector for connection with DCS or PLC

Browse

CBL-2HE1016/384-2

Browse

VE4003S2B4_SE4003S2B4

Emerson

DeltaV™

Analog Input card, 8 channel, 4-20 mA, HART, 2-wire, 16 pin Mass Termination Block

Max. CBL Length : 5m
38
INT-AI-HE10

8 channels - Analog Input (4-20mA) 2, 4 wires. HE10-16 connector for connection with DCS or PLC.

Browse

CBL-2HE1016/384-2

Browse

VE4003S3B4

Emerson

DeltaV™

Analog Input card, 8 channel, 1 - 5 Vdc, 16 pin Mass Termination Block

Max. CBL Length : 5m
40
INT-AI-4W-F-HE10

8 channels - Analog Input For (4-20mA) 4 wires or 1-5V with fuse (50mA). HE10-16 connector for connection with DCS or PLC. Screw terminals for process signals connection

Browse

CBL-2HE1016/384-2

Browse

VE4003S3B4

Emerson

DeltaV™

Analog Input card, 8 channel, 1 - 5 Vdc, 16 pin Mass Termination Block

Max. CBL Length : 5m
81
INT-AO-HE10

8 channels - Analog Output (4-20mA). HE10-16 connector for connection with DCS or PLC.

Browse

CBL-2HE1016/384-2

Browse

VE4005S2B3_SE4005S2B3

Emerson

DeltaV™

Analog Output card, 8 channel, 4-20 mA, HART, 16 pin Mass Termination Block

Max. CBL Length : 5m
83
INT-AO-F-HE10

8 channels - Analog Output (4-20mA) with fuse (50mA). HE10-16 connector for connection with DCS or PLC.

Browse

CBL-2HE1016/384-2

Browse

VE4005S2B3_SE4005S2B3

Emerson

DeltaV™

Analog Output card, 8 channel, 4-20 mA, HART, 16 pin Mass Termination Block

Max. CBL Length : 5m
85
INT-AO8-ISO

8 channels - Isolated Analog Output. (4-20mA) for standard or smart (HART protocol) valve transmitters. 1-5Vdc. SUBD25 or HE10-16 connector for connection with DCS or PLC

Browse

CBL-2HE1016/384-2

Browse

VE4005S2B3_SE4005S2B3

Emerson

DeltaV™

Analog Output card, 8 channel, 4-20 mA, HART, 16 pin Mass Termination Block

Max. CBL Length : 5m
106
INT-DI2-HE10

8 channels - Discrete Input. Interface unit for isolated inputs (24Vdc provided by an external power supply). HE10-16 connector for connection with the DCS or PLC.

Browse

CBL-2HE1016/384-2

Browse

VE4001S2T1B3_SE4001S2T1B3

Emerson

DeltaV™

Discrete Input card, 8 channel, 24 Vdc, Isolated, 16 pin Mass Termination Block

Max. CBL Length : 5m
108
INT-DI8-HE10

8 channels - Discrete Input. Interface unit for direct inputs Without fuse and relay. HE10-16 connector for connection with the DCS or PLC.

Browse

CBL-2HE1016/384-2

Browse

VE4001S2T1B3_SE4001S2T1B3

Emerson

DeltaV™

Discrete Input card, 8 channel, 24 Vdc, Isolated, 16 pin Mass Termination Block

Max. CBL Length : 5m
219
INT-DI1-HE10

8 channels - Discrete Input. Interface unit for non-isolated inputs (24Vdc provided by the input card). HE10-16 connector for connection with DCS or PLC.

Browse

CBL-2HE1016/384-2

Browse

VE4001S2T2B3_SE4001S2T2B3

Emerson

DeltaV™

Discrete Input card, 8 channel, 24 Vdc, NAMUR, Dry contact, 16 pin Mass Termination Block

>>> In this case, the line monitoring system (LFD) is not used Max. CBL Length : 5m
221
INT-DI8-HE10

8 channels - Discrete Input. Interface unit for direct inputs Without fuse and relay. HE10-16 connector for connection with the DCS or PLC.

Browse

CBL-2HE1016/384-2

Browse

VE4001S2T2B3_SE4001S2T2B3

Emerson

DeltaV™

Discrete Input card, 8 channel, 24 Vdc, NAMUR, Dry contact, 16 pin Mass Termination Block

Max. CBL Length : 5m
231
INT-DO8-DIR-HE10

8 channels - Discrete output without fuse and without relay - Direct output. HE1016 connector for DCS or PLC conenction

Browse

CBL-2HE1016/384-2

Browse

VE4002S1T1B3_SE4002S1T1B3

Emerson

DeltaV™

Discrete Output card, 8 channel, 24 Vdc, Isolated, 16 pin Mass Termination Block

Max. CBL Length : 5m
233
INT-DO8-F-DIR-HE10

8 channels - Discrete output with fuse (2A) and without relay - Direct output. HE1016 connector for DCS or PLC conenction

Browse

CBL-2HE1016/384-2

Browse

VE4002S1T1B3_SE4002S1T1B3

Emerson

DeltaV™

Discrete Output card, 8 channel, 24 Vdc, Isolated, 16 pin Mass Termination Block

Max. CBL Length : 5m
249
INT-DO8-DIR-HE10

8 channels - Discrete output without fuse and without relay - Direct output. HE1016 connector for DCS or PLC conenction

Browse

CBL-2HE1016/384-2

Browse

VE4002S1T2B3_SE4002S1T2B3

Emerson

DeltaV™

Discrete Output card, 8 channel, 24 Vdc, High-side, 16 pin Mass Termination Block

Max. CBL Length : 5m
251
INT-DO8-F-DIR-HE10

8 channels - Discrete output with fuse (2A) and without relay - Direct output. HE1016 connector for DCS or PLC conenction

Browse

CBL-2HE1016/384-2

Browse

VE4002S1T2B3_SE4002S1T2B3

Emerson

DeltaV™

Discrete Output card, 8 channel, 24 Vdc, High-side, 16 pin Mass Termination Block

Max. CBL Length : 5m
475
INT-DI3-HE10

8 channels - Discrete Input. HE10-16 connector for connection with DCS or PLC.

Browse

CBL-2HE1016/384-2

Browse

VE4001S2T2B3_SE4001S2T2B3

Emerson

DeltaV™

Discrete Input card, 8 channel, 24 Vdc, NAMUR, Dry contact, 16 pin Mass Termination Block

>>> In this case, the line monitoring system (LFD) is not used. Max. CBL Length : 5m