2
INT-AI-SUBD

8 channels - Analog Input (4-20mA) 2, 4 wires. SUBD25 connector for connection with DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4003S2B1_SE4003S2B1

Emerson

DeltaV™

Analog Input card, 8 Channels, 4-20 mA, 2-wire, HART, Terminal Block

5
INT-AI-F-SUBD

8 channels - Analog Input (4-20mA) 2, 4 wires with fuse (100mA). SUBD25 connector for connection with DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4003S2B1_SE4003S2B1

Emerson

DeltaV™

Analog Input card, 8 Channels, 4-20 mA, 2-wire, HART, Terminal Block

8
INT-AI-SUBD

8 channels - Analog Input (4-20mA) 2, 4 wires. SUBD25 connector for connection with DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4003S2B2_SE4003S2B2

Emerson

DeltaV™

Analog Input card, 8 Channels, 4-20 mA, HART, 2-wire, Fused Terminal Block (2A)

11
INT-AI-F-SUBD

8 channels - Analog Input (4-20mA) 2, 4 wires with fuse (100mA). SUBD25 connector for connection with DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4003S2B2_SE4003S2B2

Emerson

DeltaV™

Analog Input card, 8 Channels, 4-20 mA, HART, 2-wire, Fused Terminal Block (2A)

14
INT-AI-SUBD

8 channels - Analog Input (4-20mA) 2, 4 wires. SUBD25 connector for connection with DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4003S2B3

Emerson

DeltaV™

Analog Input card, 8 Channels, 4-20 mA, HART, 4-wire, Terminal Block

16
INT-AI-4W-F-SUBD

8 channels - Analog Input For (4-20mA) 4 wires or 1-5V with fuse (50mA). SUBD25 connector for connection with DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4003S2B3

Emerson

DeltaV™

Analog Input card, 8 Channels, 4-20 mA, HART, 4-wire, Terminal Block

34
INT-AI-SUBD

8 channels - Analog Input (4-20mA) 2, 4 wires. SUBD25 connector for connection with DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4003S3B3

Emerson

DeltaV™

Analog Input card, 8 Channels, 1 - 5 Vcc, Terminal Block

36
INT-AI-4W-F-SUBD

8 channels - Analog Input For (4-20mA) 4 wires or 1-5V with fuse (50mA). SUBD25 connector for connection with DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4003S3B3

Emerson

DeltaV™

Analog Input card, 8 Channels, 1 - 5 Vcc, Terminal Block

44
INT-AI-SUBD

8 channels - Analog Input (4-20mA) 2, 4 wires. SUBD25 connector for connection with DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4033S2B1_SE4033S2B1

Emerson

DeltaV™

Analog Input card, 8 Channels, 4-20 mA, HART, (switch pos : 2 wires), Redundant Terminal Block

45
INT-AI-F-SUBD

8 channels - Analog Input (4-20mA) 2, 4 wires with fuse (100mA). SUBD25 connector for connection with DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4033S2B1_SE4033S2B1

Emerson

DeltaV™

Analog Input card, 8 Channels, 4-20 mA, HART, (switch pos : 2 wires), Redundant Terminal Block

49
INT-AI-F-SUBD

8 channels - Analog Input (4-20mA) 2, 4 wires with fuse (100mA). SUBD25 connector for connection with DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4033S2B1_SE4033S2B1

Emerson

DeltaV™

Analog Input card, 8 Channels, 4-20 mA, HART, (switch pos : 4 wires), Redundant, Terminal Block

50
INT-AI-4W-F-SUBD

8 channels - Analog Input For (4-20mA) 4 wires or 1-5V with fuse (50mA). SUBD25 connector for connection with DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4033S2B1_SE4033S2B1

Emerson

DeltaV™

Analog Input card, 8 Channels, 4-20 mA, HART, (switch pos : 4 wires), Redundant, Terminal Block

65
INT-AO-SUBD

8 channels - Analog Output (4-20mA). SUBD25 connector for connection with DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4005S2B1_SE4005S2B1

Emerson

DeltaV™

Analog Output card, 8 Channels, 4-20 mA, HART, Terminal Block

67
INT-AO-F-SUBD

8 channels - Analog Output (4-20mA) with fuse (50mA). SUBD connector for connection with DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4005S2B1_SE4005S2B1

Emerson

DeltaV™

Analog Output card, 8 Channels, 4-20 mA, HART, Terminal Block

69
INT-AO8-ISO

8 channels - Isolated Analog Output. (4-20mA) for standard or smart (HART protocol) valve transmitters. 1-5Vdc. SUBD25 or HE10-16 connector for connection with DCS or PLC

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4005S2B1_SE4005S2B1

Emerson

DeltaV™

Analog Output card, 8 Channels, 4-20 mA, HART, Terminal Block

71
INT-AO-SUBD

8 channels - Analog Output (4-20mA). SUBD25 connector for connection with DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4005S2B2_SE4005S2B2

Emerson

DeltaV™

Analog Output card, 8 Channels, 4-20 mA, HART, Fused Terminal Block (2A)

73
INT-AO-F-SUBD

8 channels - Analog Output (4-20mA) with fuse (50mA). SUBD connector for connection with DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4005S2B2_SE4005S2B2

Emerson

DeltaV™

Analog Output card, 8 Channels, 4-20 mA, HART, Fused Terminal Block (2A)

75
INT-AO8-ISO

8 channels - Isolated Analog Output. (4-20mA) for standard or smart (HART protocol) valve transmitters. 1-5Vdc. SUBD25 or HE10-16 connector for connection with DCS or PLC

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4005S2B2_SE4005S2B2

Emerson

DeltaV™

Analog Output card, 8 Channels, 4-20 mA, HART, Fused Terminal Block (2A)

89
INT-AO-SUBD

8 channels - Analog Output (4-20mA). SUBD25 connector for connection with DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4035S2B1_SE4035S2B1

Emerson

DeltaV™

Analog Output card, 8 Channels, 4-20 mA, HART, Redundant, Terminal Block

91
INT-AO-F-SUBD

8 channels - Analog Output (4-20mA) with fuse (50mA). SUBD connector for connection with DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4035S2B1_SE4035S2B1

Emerson

DeltaV™

Analog Output card, 8 Channels, 4-20 mA, HART, Redundant, Terminal Block

93
INT-AI8-ISO

8 channels - Isolated Analog Input. (4-20mA) 2,4 wires for standard or smart (HART protocol) transmitters. 1-5Vdc. SUBD25 or HE10-16 connector for connection with DCS or PLC

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4035S2B1_SE4035S2B1

Emerson

DeltaV™

Analog Output card, 8 Channels, 4-20 mA, HART, Redundant, Terminal Block

98
INT-DI2-SUBD

8 channels - Discrete Input. Interface unit for isolated inputs (24Vdc provided by an external power supply). SUBD25 connector for connection with the DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4001S2T1B1_SE4001S2T1B1

Emerson

DeltaV™

Discrete Input card, 8 Channels, 24 Vdc, Isolated, Terminal Block

100
INT-DI8-SUBD

8 channels - Discrete Input. Interface unit for direct inputs Without fuse and relay. SUBD25 connector for connection with the DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4001S2T1B1_SE4001S2T1B1

Emerson

DeltaV™

Discrete Input card, 8 Channels, 24 Vdc, Isolated, Terminal Block

102
INT-DI2-SUBD

8 channels - Discrete Input. Interface unit for isolated inputs (24Vdc provided by an external power supply). SUBD25 connector for connection with the DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4001S2T1B2_SE4001S2T1B2

Emerson

DeltaV™

Discrete Input card, 8 Channels, 24 Vdc, Isolated, Fused Terminal Block (2A)

104
INT-DI8-SUBD

8 channels - Discrete Input. Interface unit for direct inputs Without fuse and relay. SUBD25 connector for connection with the DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4001S2T1B2_SE4001S2T1B2

Emerson

DeltaV™

Discrete Input card, 8 Channels, 24 Vdc, Isolated, Fused Terminal Block (2A)

110
INT-DI1-SUBD

8 channels - Discrete Input. Interface unit for non-isolated inputs (24Vdc provided by the input card). SUBD25 connector for connection with the DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4001S2T2B1_SE4001S2T2B1

Emerson

DeltaV™

Discrete Input card, 8 Channels, 24 Vdc, NAMUR, Dry contact, Terminal Block

>>> In this case, the line monitoring system (LFD) is not used
112
INT-DI8-SUBD

8 channels - Discrete Input. Interface unit for direct inputs Without fuse and relay. SUBD25 connector for connection with the DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4001S2T2B1_SE4001S2T2B1

Emerson

DeltaV™

Discrete Input card, 8 Channels, 24 Vdc, NAMUR, Dry contact, Terminal Block

114
INT-DI8-ISO24DC-SUBD

8 channels - Isolated Discrete Input Interface unit SUBD25 connector for connection with DCS or PLC

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4001S2T2B1_SE4001S2T2B1

Emerson

DeltaV™

Discrete Input card, 8 Channels, 24 Vdc, NAMUR, Dry contact, Terminal Block

117
INT-DI8-SUBD

8 channels - Discrete Input. Interface unit for direct inputs Without fuse and relay. SUBD25 connector for connection with the DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4001S2T2B2_SE4001S2T2B2

Emerson

DeltaV™

Discrete Input card, 8 Channels, 24 Vdc, NAMUR, Dry contact, Fused Terminal Block (2A)

119
INT-DI8-ISO24DC-SUBD

8 channels - Isolated Discrete Input Interface unit SUBD25 connector for connection with DCS or PLC

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4001S2T2B2_SE4001S2T2B2

Emerson

DeltaV™

Discrete Input card, 8 Channels, 24 Vdc, NAMUR, Dry contact, Fused Terminal Block (2A)

122
INT-DI8-SUBD

8 channels - Discrete Input. Interface unit for direct inputs Without fuse and relay. SUBD25 connector for connection with the DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4001S3T1B1_SE4001S3T1B1

Emerson

DeltaV™

Discrete Input card, 8 Channels, 120 Vac, Isolated, Terminal Block

124
INT-DI8-SUBD

8 channels - Discrete Input. Interface unit for direct inputs Without fuse and relay. SUBD25 connector for connection with the DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4001S3T1B2_SE4001S3T1B2

Emerson

DeltaV™

Discrete Input card, 8 Channels, 120 Vac, Isolated, Fused Terminal Block (2A)

126
INT-DI1-SUBD

8 channels - Discrete Input. Interface unit for non-isolated inputs (24Vdc provided by the input card). SUBD25 connector for connection with the DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4001S3T2B1_SE4001S3T2B1

Emerson

DeltaV™

Discrete Input card, 8 Channels, 120 Vac, Dry contact, Terminal Block

128
INT-DI8-SUBD

8 channels - Discrete Input. Interface unit for direct inputs Without fuse and relay. SUBD25 connector for connection with the DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4001S3T2B1_SE4001S3T2B1

Emerson

DeltaV™

Discrete Input card, 8 Channels, 120 Vac, Dry contact, Terminal Block

130
INT-DI8-SUBD

8 channels - Discrete Input. Interface unit for direct inputs Without fuse and relay. SUBD25 connector for connection with the DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4001S3T2B2_SE4001S3T2B2

Emerson

DeltaV™

Discrete Input card, 8 Channels, 120 Vac, Dry contact, Fused Terminal Block (2A)

132
INT-DI2-SUBD

8 channels - Discrete Input. Interface unit for isolated inputs (24Vdc provided by an external power supply). SUBD25 connector for connection with the DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4001S4T1B1

Emerson

DeltaV™

Discrete Input card, 8 Channels, 230 Vac, Isolated, Terminal Block

134
INT-DI8-SUBD

8 channels - Discrete Input. Interface unit for direct inputs Without fuse and relay. SUBD25 connector for connection with the DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4001S4T1B1

Emerson

DeltaV™

Discrete Input card, 8 Channels, 230 Vac, Isolated, Terminal Block

136
INT-DI8-SUBD

8 channels - Discrete Input. Interface unit for direct inputs Without fuse and relay. SUBD25 connector for connection with the DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4001S4T1B2

Emerson

DeltaV™

Discrete Input card, 8 Channels, 230 Vac, Isolated, Fused Terminal Block (2A)

138
INT-DI1-SUBD

8 channels - Discrete Input. Interface unit for non-isolated inputs (24Vdc provided by the input card). SUBD25 connector for connection with the DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4001S4T2B1

Emerson

DeltaV™

Discrete Input card, 8 Channels, 230 Vac, Dry contact, Terminal Block

140
INT-DI8-SUBD

8 channels - Discrete Input. Interface unit for direct inputs Without fuse and relay. SUBD25 connector for connection with the DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4001S4T2B1

Emerson

DeltaV™

Discrete Input card, 8 Channels, 230 Vac, Dry contact, Terminal Block

142
INT-DI8-SUBD

8 channels - Discrete Input. Interface unit for direct inputs Without fuse and relay. SUBD25 connector for connection with the DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4001S4T2B2

Emerson

DeltaV™

Discrete Input card, 8 Channels, 230 Vac, Dry contact, Fused Terminal Block (2A)

174
INT-DI1-SUBD

8 channels - Discrete Input. Interface unit for non-isolated inputs (24Vdc provided by the input card). SUBD25 connector for connection with the DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4031S2T2B1_SE4031S2T2B1

Emerson

DeltaV™

Discrete Input card, 8 Channels, 24 Vdc, NAMUR, Dry contact, Redundant, Terminal Block

>>> In this case, the line monitoring system (LFD) is not used
176
INT-DI8-SUBD

8 channels - Discrete Input. Interface unit for direct inputs Without fuse and relay. SUBD25 connector for connection with the DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4031S2T2B1_SE4031S2T2B1

Emerson

DeltaV™

Discrete Input card, 8 Channels, 24 Vdc, NAMUR, Dry contact, Redundant, Terminal Block

178
INT-DI8-ISO24DC-SUBD

8 channels - Isolated Discrete Input Interface unit SUBD25 connector for connection with DCS or PLC

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4031S2T2B1_SE4031S2T2B1

Emerson

DeltaV™

Discrete Input card, 8 Channels, 24 Vdc, NAMUR, Dry contact, Redundant, Terminal Block

225
INT-DO8-DIR-SUBD

8 channels - Discrete output without fuse and without relay - Direct output. SUBD25 connector for DCS or PLC conenction

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4002S1T1B1_SE4002S1T1B1

Emerson

DeltaV™

Discrete Output card, 8 Channels, 24 Vdc, Isolated, Terminal Block

227
INT-DO8-F-DIR-SUBD

8 channels - Discrete output with fuse (2A) and without relay - Direct output. SUBD15 connector for DCS or PLC conenction.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4002S1T1B1_SE4002S1T1B1

Emerson

DeltaV™

Discrete Output card, 8 Channels, 24 Vdc, Isolated, Terminal Block

229
INT-DO8-DIR-SUBD

8 channels - Discrete output without fuse and without relay - Direct output. SUBD25 connector for DCS or PLC conenction

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4002S1T1B2_SE4002S1T1B2

Emerson

DeltaV™

Discrete Output card, 8 Channels, 24 Vdc, Isolated, Fused Terminal Block (2A)

235
INT-DO8-DIR-SUBD

8 channels - Discrete output without fuse and without relay - Direct output. SUBD25 connector for DCS or PLC conenction

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4002S1T2B1_SE4002S1T2B1

Emerson

DeltaV™

Discrete Output card, 8 Channels, 24 Vdc, High-side, Terminal Block

237
INT-DO8-F-DIR-SUBD

8 channels - Discrete output with fuse (2A) and without relay - Direct output. SUBD15 connector for DCS or PLC conenction.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4002S1T2B1_SE4002S1T2B1

Emerson

DeltaV™

Discrete Output card, 8 Channels, 24 Vdc, High-side, Terminal Block

243
INT-DO8-DIR-SUBD

8 channels - Discrete output without fuse and without relay - Direct output. SUBD25 connector for DCS or PLC conenction

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4002S1T2B2_SE4002S1T2B2

Emerson

DeltaV™

Discrete Output card, 8 Channels, 24 Vdc, High-side, Fused Terminal Block (2A)

270
INT-DO8-F-DIR-SUBD

8 channels - Discrete output with fuse (2A) and without relay - Direct output. SUBD15 connector for DCS or PLC conenction.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4002S2T1B1_SE4002S2T1B1

Emerson

DeltaV™

Discrete Output card, 8 Channels, 115/230 Vac, Isolated, Terminal Block

272
INT-DO8-DIR-SUBD

8 channels - Discrete output without fuse and without relay - Direct output. SUBD25 connector for DCS or PLC conenction

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4002S2T1B2_SE4002S2T1B2

Emerson

DeltaV™

Discrete Output card, 8 Channels, 115/230 Vac, Isolated, Fused Terminal Block (2A)

274
INT-DO8-F-DIR-SUBD

8 channels - Discrete output with fuse (2A) and without relay - Direct output. SUBD15 connector for DCS or PLC conenction.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4002S2T2B1_SE4002S2T2B1

Emerson

DeltaV™

Discrete Output card, 8 Channels, 115/230 Vac, High-side, Terminal Block

276
INT-DO8-DIR-SUBD

8 channels - Discrete output without fuse and without relay - Direct output. SUBD25 connector for DCS or PLC conenction

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4002S2T2B2_SE4002S2T2B2

Emerson

DeltaV™

Discrete Output card, 8 Channels, 115/230 Vac, High-side, Fused Terminal Block (2A)

294
INT-DO8-DIR-SUBD

8 channels - Discrete output without fuse and without relay - Direct output. SUBD25 connector for DCS or PLC conenction

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4032S1T2B1_SE4032S1T2B1

Emerson

DeltaV™

Discrete Output card, 8 Channels, 24 Vdc, High-side, Redundant, Terminal block

296
INT-DO8-F-DIR-SUBD

8 channels - Discrete output with fuse (2A) and without relay - Direct output. SUBD15 connector for DCS or PLC conenction.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4032S1T2B1_SE4032S1T2B1

Emerson

DeltaV™

Discrete Output card, 8 Channels, 24 Vdc, High-side, Redundant, Terminal block

471
INT-DI3-SUBD

8 channels - Discrete Input. SUBD25 connector for connection with the DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4001S2T2B1_SE4001S2T2B1

Emerson

DeltaV™

Discrete Input card, 8 Channels, 24 Vdc, NAMUR, Dry contact, Terminal Block

>>> In this case, the line monitoring system (LFD) is used
473
INT-DI3-SUBD

8 channels - Discrete Input. SUBD25 connector for connection with the DCS or PLC.

Browse

CBL-SUBD25FSHD/16W/514

Browse

VE4031S2T2B1_SE4031S2T2B1

Emerson

DeltaV™

Discrete Input card, 8 Channels, 24 Vdc, NAMUR, Dry contact, Redundant, Terminal Block

>>> In this case, the line monitoring system (LFD) is used